Skip to main content
Version: 2606

EPLB - Lublin

Aerodrome general information

ARPLocalizationElevation
51° 14' 21'' N 022° 42' 51'' E6 NM east from city centre637 ft

Aerodrome category for firefighting: CAT 7 ICAO

Runway characteristics

|Designations|True bearing|Magnetic bearing|Runway dimensions (m)|SWY dimensions (m)|Strip dimensions (m)|RESA (m)| |-|-|-|-|-|-| |07|077°|072°|2520 x 45|NIL|2640 x 300|180 x 90| |25|257°|252°|2520 x 45|NIL|2640 x 300|180 x 90|

Declared distances

RunwayTORA (m)TODA (m)ASDA (m)LDA (m)Remarks
072520252025202520NIL
07127112711271NILINTERSECTION TAKE OFF TWY A
252520252025202520NIL
25127112711271NILINTERSECTION TAKE OFF TWY A

Air traffic services airspace

Airspace designationsVertical limitsAirspace classificationATS unitTransition altitude
LUBLIN CTRGND - 1500 ftDLUBLIN TOWER (136.430 MHz)6500 ft

Radio navigation and landing aids

TypeIDFrequency/channel
DME 25ISWICH 56Y
DVOR/DMESWI112.200 MHz / CH 59X
ILS GP 25-330.950 MHz
ILS LOC 25ISWI111.950 MHz

Local aerodrome regulations

Datalink clearances at the Lublin airport are not available.

Ground movement procedures

Stand 11 can be used as holding position for category D aircraft. Stand 10 is used for deicing.

TWYRESTRICTIONREMARKS

Aircraft DE-ICING

De-icing is possible only on stand no. 10 with engines turned off.

VFR traffic

During high traffic load, aircraft in VFR flight may be instructed to hold on one of the published holdings: — on the north side of the aerodrome TANGO, — on the south side of the aerodrome SIERRA.

Low Visibility Procedures (LVP)

LVP operations will be commenced when any of the RVR falls below 550 m and/or the cloud ceiling falls below 200 ft.

Pilots are informed about LVP being in operation by radio, with use of following phraseology: “Low visibility procedures in operation. CAT II in operation”. If weather conditions does not allow CAT II approaches the following phraseology should be used instead: “Low visibility procedures in operation. CAT II not available”.

LVP will be terminated when all RVRs increase to 600 m or above and ceiling rises above 200 ft and a continuing improvement is anticipated.

PhaseRVRCloud ceiling or VV
Preparation≤ 800 m≤ 300 ft (90m)
LVP< 550 m< 200 ft (60m)
Suspension≥ 600 m≥ 200 ft (60m)*

During LVP for departure and landing only runway 25 should be used. Runway 07 can be used for departure on pilot request. After landing runway should be vacated via taxiway A and reported to ATC.

Minimum RVR for departure is 125 m.

OperationRVR
Departure≥ 125 m
Arrival (RWY 25)≥ 300 m (CAT II)